How To Quote For EICR/Fixed Wire Testing

If a customer asks if we do EICR/Fixed wire testing ask them the below:

In order for us to give you an accurate quote can you please email me a picture of all the fuse boards/consumer units located in the property.

Once the customer has sent you the pictures send the to mrmtspark@gmail.com (Mick) and ask hime to provide a quote to you. You will also need to send him the customers address.

He will then send you back a quote that will look something like below:

————————————————————————————————————————————————————-

To carry out Electrical Installation Condition Reporting for 1Nr
panel board, and1Nr single phase board as attached photos

Tests to include - 100% Visual inspection of surface fixed wiring and
accessories where accessible, 20% fixed wiring testing, including earth loop impedance, insulation
resistance, continuity and RCD where applicable as guidance note refers.

Limitations including the reasons
Primary supply protective device verification due incoming device seals
PV supply equipment/generator equipment
Circuits feeding IT equipment and UPS systems, (visual inspection only),
Insulation resistance testing between live conductors due to
connection of electronic equipment
No high level works, no lifting or moving of furniture or equipment for accessibility
Machinery, CCTV, boiler systems, fire or intruder alarm systems

Total £390.00
————————————————————————————————————————————————————-

You then send this quote to the customer but adding 25%+vat to the total price, so it looks like the below: (to add 25% just do this calculation 390 X 1.25 = )

————————————————————————————————————————————————————-

To carry out Electrical Installation Condition Reporting for 1Nrpanel board, and
1Nr single phase board as attached photos

Tests to include - 100% Visual inspection of surface fixed wiring and
accessories where accessible, 20% fixed wiring testing, including earth loop impedance, insulation
resistance, continuity and RCD where applicable as guidance note refers.

Limitations including the reasons
Primary supply protective device verification due incoming device seals
PV supply equipment/generator equipment
Circuits feeding IT equipment and UPS systems, (visual inspection only),Insulation resistance testing between live conductors due to
connection of electronic equipment
No high level works, no lifting or moving of furniture or equipment for accessibilityMachinery, CCTV, boiler systems, fire or intruder alarm systems

Total £487.50+vat

————————————————————————————————————————————————————-

If the customer approves, email Mick and ask him for the next available date.